devel:blueprints:consolidated-interface-table [2009/02/06 10:53]
morten created
devel:blueprints:consolidated-interface-table [2009/03/19 13:26] (current)
morten
Line 1: Line 1:
-A preliminary schema ​for a new table: +====== Rationale ====== 
-<code sql>+NAV has for many years had an artifical divide between switch ports and router interfaces, which are stored in each their table (//swport// and //​gwport//​). 
 +Conceptually,​ they are all just network interfaces, which share a set of attributes. ​ On routers, interfaces can also operate on the IP layer, which adds some attributes.
  
 +NAV contains a lot of duplicate and/or complex code to work with both swports and gwports, since they are in separate tables. ​ Also, many data structures and lookups are complicated by the fact that the current model requires an swport/​gwport to be related to a module, not to a netbox. ​ In reality, interfaces are uniquely adressed within a single SNMP agent, and we cannot always determine which module an interface is physically attached to.  For devices that don't really have modules, NAV will currently create a pseudo-module related to the same device (serial number) as the netbox, just so it can add ports to the netbox. ​ We aim to make an interface'​s relationship to a module an optional bonus, and thus make many joins with the module table superfluous.
 +
 +
 +====== New schema ======
 +A preliminary schema for a new interface table:
 +<code sql>
 -- New consolidated interface table -- New consolidated interface table
 -- See MIB-II, IF-MIB, RFC 1229 -- See MIB-II, IF-MIB, RFC 1229
 CREATE TABLE interface ( CREATE TABLE interface (
-  interfaceid SERIAL, +  interfaceid SERIAL ​NOT NULL
-  netboxid INT4,+  netboxid INT4 NOT NULL,
   moduleid INT4,   moduleid INT4,
   ifindex INT4 NOT NULL,   ifindex INT4 NOT NULL,
Line 14: Line 21:
   speed DOUBLE PRECISION,   speed DOUBLE PRECISION,
   ifphysaddress MACADDR,   ifphysaddress MACADDR,
-  ifadminstatus INT4,  +  ifadminstatus INT4, -- 1=up, 2=down, 3=testing 
-  ifoperstatus INT4,+  ifoperstatus INT4,  -- 1=up, 2=down, 3=testing, 4=unknown, 5=dormant, 6=notPresent,​ 7=lowerLayerDown
   iflastchange INT4,   iflastchange INT4,
   ifconnectorpresent BOOLEAN,   ifconnectorpresent BOOLEAN,
Line 30: Line 37:
   to_interfaceid INT4,    to_interfaceid INT4, 
  
 +  gone_since TIMESTAMP,
   ​   ​
   CONSTRAINT interface_pkey PRIMARY KEY (interfaceid),​   CONSTRAINT interface_pkey PRIMARY KEY (interfaceid),​
Line 51: Line 59:
              ​UNIQUE (interfaceid,​ netboxid)              ​UNIQUE (interfaceid,​ netboxid)
 ); );
 +
 </​code>​ </​code>​
 +
 +The gwport table contains a field dubbed ''​metric'',​ which represents OSPF metric, where applicable. ​ A router interface may in reality use multiple routing protocols, so this piece of information should be in an ancillary table:
 +
 +<code sql>
 +-- Routing protocol attributes
 +CREATE TABLE rproto_attr (
 +  id SERIAL NOT NULL,
 +  interfaceid INT4 NOT NULL,
 +  protoname VARCHAR NOT NULL, -- bgp/​ospf/​isis
 +  metric INT4,
 +
 +  CONSTRAINT rproto_attr_pkey ​
 +             ​PRIMARY KEY (id),
 +  CONSTRAINT rproto_attr_interfaceid_fkey
 +             ​FOREIGN KEY (interfaceid)
 +             ​REFERENCES interface (interfaceid)
 +);
 +</​code>​
 +
devel/blueprints/consolidated-interface-table.1233917623.txt.gz · Last modified: 2009/02/06 10:53 by morten